Bench & Gauge

Fluke 561 Ir Thermometer Buying Guide

The Fluke 561 is a handheld infrared thermometer with a unique dual-function design: a single-unit contact and non-contact thermometer, paired with a Type K thermocouple probe for direct-contact measurement. The core trade-off is between the convenience of fast non-contact surface scanning and the accuracy limits of IR on reflective or emissivity-variable targets, versus a slower but definitive contact probe. The decision rule: buy the 561 only if you need both IR scanning and a built-in Type K probe with a single device; if you only need non-contact spot checks, a simpler fixed-emissivity IR gun is more cost-effective.

IR Range:-40 to 550°C (-40 to 1022°F)Distance-to-Spot:12:1Emissivity:Adjustable 0.1 to 1.00Contact Probe:Type K sub-miniature

Key takeaways

  • The Fluke 561 is a combination IR and contact thermometer with a built-in Type K thermocouple input, accepting standard sub-miniature Type K plugs for direct surface and immersion probes.
  • IR measurement distance-to-spot ratio is 12:1, meaning at 1 meter the measurement spot is roughly 8.3 cm—critical for small targets where spot size must fit inside the surface being measured.
  • Adjustable emissivity from 0.1 to 1.00 allows calibration to non-blackbody surfaces; default emissivity is 0.95 for most organic and painted surfaces, but shiny metals need correction or a contact probe.

At a glance

Price range
Varies by listing
Category
Calibration Equipment & Standards
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • The Fluke 561 is a combination IR and contact thermometer with a built-in Type K thermocouple input, accepting standard sub-miniature Type K plugs for direct surface and immersion probes.
  • IR measurement distance-to-spot ratio is 12:1, meaning at 1 meter the measurement spot is roughly 8.3 cm—critical for small targets where spot size must fit inside the surface being measured.
  • Adjustable emissivity from 0.1 to 1.00 allows calibration to non-blackbody surfaces; default emissivity is 0.95 for most organic and painted surfaces, but shiny metals need correction or a contact probe.
  • The 561 is specified for a broad temperature range from -40°C to 550°C (-40°F to 1022°F) in IR mode and a similar range with the included Type K probe, with 1°C/1°F resolution.

Best use cases

  • Best fit: HVAC technicians diagnosing supply/return air temperatures with the IR mode and verifying duct surface temperatures with the Type K probe—one tool for both tasks.
  • Best fit: Food safety and sanitation inspectors who need to scan surface temperatures quickly and then check internal temperatures of a sample with a penetration probe.
  • Wrong fit: Industrial high-temperature kiln or forge monitoring where temperatures exceed 550°C—choose a higher-range IR thermometer like the Fluke 572 or a pyrometer instead.
  • Wrong fit: Laboratory-grade emissivity-compensated measurements on low-emissivity metals—a contact probe or a more advanced IR camera with adjustable emissivity tables is required.

Buying tips

  • Match the distance-to-spot ratio to your target size: the 12:1 ratio requires the target to be at least the spot diameter at your working distance; for a 2 cm target, keep distance under 24 cm.
  • Confirm the Type K probe connector type: the 561 accepts standard sub-miniature Type K plugs; ensure any replacement or additional probes use this standard, not proprietary connectors.
  • Check emissivity adjustability: if measuring shiny metal surfaces, a fixed emisivity of 0.95 will give inaccurate readings; the 561's adjustable emissivity helps, but contact probes are still better for bare metals.
  • Consider battery type: the 561 uses a 9V battery; buying rechargeable 9V batteries and a charger is a practical upgrade for heavy daily use, and always carry a spare.

Specs

IR Range-40 to 550°C (-40 to 1022°F)
Distance-to-Spot12:1
EmissivityAdjustable 0.1 to 1.00
Contact ProbeType K sub-miniature

Related searches

What to check before buying

  • Ensure you have a Type K probe with a standard sub-miniature connector if you intend to use contact mode; the 561 typically ships with one probe, but extra probes for different surfaces (air, immersion, surface) are separate purchases.
  • Confirm that the temperature range covers your application: -40°C to 550°C for IR mode; if you need lower or higher, look at other models.
  • Check the environment: the 561 is not rated for use in wet or condensing environments; avoid steam or water spray during measurement.
  • Verify power: the 9V battery is widely available, but for extended field use, carry a spare and consider a battery eliminator if working near a power source.