Airy Technology P311 Buying Guide
The Airy Technology P311 is a handheld optical particle counter used for indoor air quality (IAQ) spot checks, HVAC diagnostics, and cleanroom verification. The primary trade-off is between laser-diode optical engines and lower-cost photodiode sensors: laser units deliver stable 0.3 µm sensitivity across six size channels, while photodiode models lose accuracy below 0.5 µm and drift with temperature. Buy the P311 only if you need true sub-micron particle counting with a zero-count filter for calibration checks; skip it if you only need relative PM2.5 trend data, where a low-cost particulate monitor or a calibrated IAQ logger suffices.
Key takeaways
- Handheld optical particle counter architecture with a laser-diode light source and photodetector, resolving six size channels from 0.3 µm to 10 µm for ISO 14644 cleanroom and IAQ screening.
- Built for spot-check portability: internal sample pump, onboard battery, and a built-in filter for zero-count verification before each measurement session to confirm sensor health.
- Accuracy depends on sample flow stability and zero-check discipline: the zero filter provides a true zero-particle baseline, distinguishing a functional laser engine from a drifted or contaminated optical chamber.
At a glance
- Category
- Environmental & Indoor Air Measurement
- Status
- Listings available
- Last updated
- Nov 28, 2026
Current offers
Highlights
- Handheld optical particle counter architecture with a laser-diode light source and photodetector, resolving six size channels from 0.3 µm to 10 µm for ISO 14644 cleanroom and IAQ screening.
- Built for spot-check portability: internal sample pump, onboard battery, and a built-in filter for zero-count verification before each measurement session to confirm sensor health.
- Accuracy depends on sample flow stability and zero-check discipline: the zero filter provides a true zero-particle baseline, distinguishing a functional laser engine from a drifted or contaminated optical chamber.
- Sampling accessories are model-specific: isokinetic probes and tubing lengths for the P311 inlet must match the inlet diameter and flow rate; using a different probe changes the sampled volume and biases counts.
Best use cases
- Best fit: commissioning or verifying a cleanroom or hospital isolation room where 0.3 µm and 0.5 µm counts are required—choose the P311 with a zero-count filter and isokinetic probe for certification runs.
- Best fit: HVAC or facilities diagnostics where you compare particle counts before and after filter changes—use it as a before/after differential meter rather than an absolute regulatory instrument.
- Wrong fit: continuous overnight or multi-day monitoring—the P311 is a handheld spot checker, so for trend logging choose a fixed-mount particle sensor or an IAQ logger with data export.
- Wrong fit: outdoor dust or wildfire smoke-only screening where only PM2.5 mass concentration matters—skip the P311 and use a low-cost PM2.5 monitor; particle counters report count-per-volume, not mass.
Buying tips
- Demand laser-diode optical engine specifications: photodiode-based counters lose 0.3 µm sensitivity and drift, while laser units hold six-channel resolution from 0.3 to 10 µm.
- Verify zero-count filter inclusion: without a zero filter you cannot distinguish a clean air sample from a dirty optical chamber, so require a zero-check accessory in the kit.
- Match the isokinetic probe to the inlet: probe diameter and flow rate must match the P311's sample flow to avoid biased counts from non-isokinetic sampling in moving air.
- Check calibration documentation: a particle counter's counts are only meaningful with a traceable calibration certificate, and recalibration intervals are typically annual for IAQ and cleanroom use.
Specs
| Particle Sizing Range | 0.3–10 µm, six size channels |
|---|---|
| Light Source | Laser diode vs photodiode sensor |
| Form Factor | Handheld spot checker, internal pump |
| Calibration Check | Zero-count filter required |
Alternatives to compare
Related searches
What to check before buying
- Confirm your application's size-channel requirement: 0.3 µm and 0.5 µm channels require a laser-diode counter like the P311, while 0.5 µm+ only may accept a lower-cost photodiode unit.
- Measure your sampling environment: handheld spot checks need a reachable inlet height and a stable surface, while ceiling or duct work requires a probe extension matched to the P311 inlet.
- Verify local power and battery needs: the P311 is a portable handheld with an internal battery, so confirm the charger voltage and plug standard for your region before ordering.
- Check companion parts: zero-count filter, isokinetic probe, and replacement tubing are model-specific, and a missing zero filter prevents proper pre-measurement verification.