Fieldpiece Temperature Probe Buying Guide
Fieldpiece temperature probes are thermistor-based accessories that plug into Fieldpiece HVAC/R meters and manifolds, converting electrical resistance into pipe, air, or liquid temperature readings. The core trade-off is probe type (pipe-clamp vs. immersion vs. air) and connector compatibility with your existing Fieldpiece instrument family. Buy only probes whose plug physically matches your meter's thermistor jack and whose temperature range covers your application—generic thermocouples will not read correctly on Fieldpiece thermistor inputs.
Key takeaways
- Fieldpiece thermistor probes use a 10k-ohm NTC element with a proprietary 2-pin plug; they are not interchangeable with K-type thermocouple accessories.
- Pipe-clamp models (e.g., ATC1, RTC1) use spring-loaded jaws for 1/4- to 1-1/8-inch copper; immersion and air probes use stainless stems or perforated cages.
- Probe accuracy is typically ±1°F to ±2°F across -40°F to 250°F; high-temp versions extend to 500°F+ for flue and oven work.
At a glance
- Price range
- Varies by listing
- Category
- Test Leads, Probes, Fixtures & Accessories
- Last updated
- Nov 28, 2026
Current offers
Highlights
- Fieldpiece thermistor probes use a 10k-ohm NTC element with a proprietary 2-pin plug; they are not interchangeable with K-type thermocouple accessories.
- Pipe-clamp models (e.g., ATC1, RTC1) use spring-loaded jaws for 1/4- to 1-1/8-inch copper; immersion and air probes use stainless stems or perforated cages.
- Probe accuracy is typically ±1°F to ±2°F across -40°F to 250°F; high-temp versions extend to 500°F+ for flue and oven work.
- Cable length ranges from 3 to 6 feet; longer leads suit rooftop and walk-in applications but add resistance and signal noise if coiled near power wiring.
Best use cases
- Choose a pipe-clamp thermistor probe when measuring superheat/subcool on refrigerant lines—skip air probes for this task because they cannot maintain contact with curved copper.
- Choose an immersion or penetration probe for duct traverses, walk-in cooler air, or liquid lines; skip clamp probes on bare sheet-metal ducts where jaw pressure cannot seat.
- Choose a high-temperature probe with a stainless sheath for flue-gas or oven readings; skip standard PVC-cable probes above 250°F where insulation degrades.
Buying tips
- Match the connector: Fieldpiece meters use a 2-pin thermistor jack; confirm your meter accepts NTC thermistors, not K-type thermocouples, before buying any probe.
- Size the clamp jaw to your pipe: 1/4-inch and 3/8-inch lines need a small-jaw clamp; 7/8-inch and 1-1/8-inch suction lines need a wide-jaw model for full contact.
- Check temperature range against your task: standard probes cover -40°F to 250°F; flue and oven work requires a 500°F+ rating with a stainless or fiberglass-insulated cable.
- Prefer replaceable-cable or modular probes for field service—fixed-cable probes fail at the strain relief and cannot be repaired without replacing the whole unit.
Specs
| Sensor Type | 10k NTC thermistor (2-pin) |
|---|---|
| Probe Style | Clamp / immersion / air / penetration |
| Temp Range | -40°F to 250°F (std); 500°F+ (hi-temp) |
| Cable Length | 3-6 ft (PVC or high-temp) |
Related searches
What to check before buying
- Confirm your Fieldpiece meter or manifold has a 2-pin thermistor input and is not exclusively K-type thermocouple; mismatched inputs give open-circuit or erratic readings.
- Measure the pipe diameter at the measurement point: clamp jaws must span the full circumference; a 1/4-inch jaw will not seat on a 7/8-inch suction line.
- Check ambient and process temperature: standard PVC cable is rated to 221°F (105°C); higher temperatures require silicone or fiberglass cable and stainless sheaths.
- Verify cable length reaches from the meter hanging point to the probe location without tension; add 1-2 feet of slack for door seals and panel edges.
FAQ
Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.