High-voltage oscilloscope probes are specialized front-end attenuators that let a standard scope safely measure kilovolt-class waveforms without exceeding its input rating or compromising safety. The core trade-off is voltage-derating margin versus bandwidth and input impedance: passive HV probes reach the highest voltages but load the circuit more and roll off faster, while differential and opto-isolated probes trade voltage headroom for common-mode rejection and floating-measurement safety. Choose a probe whose certified working voltage, CAT rating, and derating curve comfortably exceed your worst-case peak, and reject any unit that lacks a defined transient rating or safety-agency marking.

Attenuation Ratio:100:1 / 1000:1 passiveMax Working Voltage:1–20 kV DC+peak (derated)Probe Type:Passive / Differential / IsolatedSafety Category:CAT I / II / III

Key takeaways

  • Passive HV probes typically divide 100:1 or 1000:1; a 1000:1 probe with 100 MΩ input presents far less circuit loading than a 100:1 unit, but bandwidth usually drops to the low hundreds of MHz.
  • Safety category and working-voltage derating matter more than headline peak voltage: CAT II ratings fall sharply as frequency rises, so verify the derating curve at your actual operating frequency.
  • Differential probes measure floating or high-side signals safely by rejecting common-mode voltage; single-ended passive HV probes require the scope ground to remain at earth potential.

At a glance

Price range
Varies by listing
Category
Test Leads, Probes, Fixtures & Accessories
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • Passive HV probes typically divide 100:1 or 1000:1; a 1000:1 probe with 100 MΩ input presents far less circuit loading than a 100:1 unit, but bandwidth usually drops to the low hundreds of MHz.
  • Safety category and working-voltage derating matter more than headline peak voltage: CAT II ratings fall sharply as frequency rises, so verify the derating curve at your actual operating frequency.
  • Differential probes measure floating or high-side signals safely by rejecting common-mode voltage; single-ended passive HV probes require the scope ground to remain at earth potential.
  • Optically isolated probes break the ground loop entirely and are the only safe choice when neither node can be referenced to earth, but they cost more and often have lower bandwidth.

Best use cases

  • Best fit for switch-mode power supply and inverter repair: a 100:1 or 1000:1 passive HV probe rated above your DC bus plus ringing margin, paired with a scope whose maximum input voltage is not exceeded.
  • Best fit for floating high-side gate-drive or motor-phase measurements: a true differential probe with common-mode rating exceeding the bus voltage, not a passive probe with the ground clip lifted.
  • Wrong fit: using a standard 10:1 passive probe on any circuit above its CAT-rated voltage—this risks arc-over inside the probe body and exposes the scope chassis to dangerous potential.
  • Skip HV probes entirely for low-voltage logic and audio work; a 10:1 or 1:1 passive probe gives better noise performance and resolution at a fraction of the cost.

Buying tips

  • Match the probe's continuous working voltage to your worst-case DC plus transient peak, then add at least 30% margin; a 1 kV-rated probe is marginal on a 800 V DC bus with switching overshoot.
  • Confirm the probe's maximum scope-side voltage does not exceed your oscilloscope's input rating—attenuation ratio and scope input impedance together determine the safe division.
  • Prefer probes with a defined derating curve plotted against frequency rather than a single headline voltage; high-frequency AC derates working voltage substantially.
  • For floating measurements, budget for a differential or isolated probe from the start; modifying a passive probe's ground lead is unsafe and voids its rating.

Specs

Attenuation Ratio100:1 / 1000:1 passive
Max Working Voltage1–20 kV DC+peak (derated)
Probe TypePassive / Differential / Isolated
Safety CategoryCAT I / II / III

Related searches

What to check before buying

  • Measure your circuit's maximum DC bus voltage, peak transient, and operating frequency, then compare against the probe's derated working voltage at that frequency.
  • Verify your oscilloscope's input connector type (BNC standard), input impedance (1 MΩ typical), and maximum input voltage before selecting an attenuation ratio.
  • Confirm the probe's safety category (CAT I/II/III) matches the installation environment—mains-derived circuits demand CAT II or higher.
  • Check that the probe includes the correct tip adapters, ground lead, and insulation accessories for your test points, and that replacement tips are available.