Phased Array Probe Buying Guide

A phased array probe is an ultrasonic transducer with multiple individually pulsed elements that steer and focus the beam electronically, enabling sector scans and weld inspection without moving the probe. The core trade-off is between element count/frequency range (resolution and coverage) and probe ruggedness/connector compatibility (durability and integration cost). Choose a probe with a documented standard connector, replaceable wear plate, and frequency range matched to your wall thickness—compromise on these and you get un-steerable beams or dead elements.

Element Count:16 / 32 / 64 / 128 elementsFrequency Range:1-10 MHz (2.25 / 5 / 7.5 MHz common)Connector Type:BNC / LEMO 00 / multi-pinElement Pitch:0.3-1.6 mm (≤ half wavelength)

Key takeaways

  • Element count (16 to 128) directly sets beam-steering resolution: 32-element probes resolve 1-2 mm flaws; 64+ elements are required for tight focal laws on thick sections.
  • Frequency (1-10 MHz) trades penetration for resolution: 2-2.25 MHz for coarse castings and thick welds, 5 MHz for general weld inspection, 7.5-10 MHz for thin-wall and near-surface defects.
  • Probe pitch (element spacing) must be ≤ half the wavelength in the test material to avoid grating lobes—at 5 MHz in steel this caps pitch near 0.6 mm.

At a glance

Price range
Varies by listing
Category
Test Leads, Probes, Fixtures & Accessories
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • Element count (16 to 128) directly sets beam-steering resolution: 32-element probes resolve 1-2 mm flaws; 64+ elements are required for tight focal laws on thick sections.
  • Frequency (1-10 MHz) trades penetration for resolution: 2-2.25 MHz for coarse castings and thick welds, 5 MHz for general weld inspection, 7.5-10 MHz for thin-wall and near-surface defects.
  • Probe pitch (element spacing) must be ≤ half the wavelength in the test material to avoid grating lobes—at 5 MHz in steel this caps pitch near 0.6 mm.
  • Connector type (BNC, LEMO 00, or proprietary multi-pin) and phasing compatibility determine whether the probe works with your flaw detector or requires an adapter.

Best use cases

  • Best fit: weld inspection on 6-50 mm steel—pick a 5 MHz, 32-64 element, 0.6-1.0 mm pitch probe with a standard LEMO or BNC connector; skip high-frequency 10 MHz probes that lose penetration beyond 20 mm.
  • Best fit: thin-wall tube and near-surface corrosion mapping—choose 7.5-10 MHz with a small footprint and integrated wedge; skip low-frequency 1-2 MHz probes that blur sub-millimeter defects.
  • Best fit: coarse-grained castings and austenitic welds—use 1-2.25 MHz, 16-32 element probes with dual-element or composite crystal design; skip standard 5 MHz probes that scatter in large grains.
  • Wrong fit: portable field work with a bare probe and no compatible wedge or connector adapter—skip probes without a replaceable wear face, which fail quickly on rough surfaces.

Buying tips

  • Match frequency to wall thickness: use 5 MHz for 6-25 mm steel, 2.25 MHz for 25-100 mm, and 7.5-10 MHz below 6 mm; outside these bands resolution or penetration degrades sharply.
  • Pick element count by focal-law need: 16 elements for simple fixed-angle scans, 32 for standard sector scans, 64-128 for tight focusing and thick-section phased array inspection.
  • Verify pitch against wavelength: pitch must be ≤ half the wavelength in the material at the highest operating frequency; at 5 MHz in steel (3.2 mm wavelength) that means ≤1.6 mm pitch.
  • Confirm connector and phasing standard—LEMO 00 and BNC are common on portable flaw detectors, while 64+ element probes often need a specific multi-pin or micro-connector matched to the instrument.

Specs

Element Count16 / 32 / 64 / 128 elements
Frequency Range1-10 MHz (2.25 / 5 / 7.5 MHz common)
Connector TypeBNC / LEMO 00 / multi-pin
Element Pitch0.3-1.6 mm (≤ half wavelength)

Related searches

What to check before buying

  • Measure the thickest and thinnest sections you will inspect; the probe frequency and element count must cover both without swapping probes mid-job.
  • Check your flaw detector's connector type and maximum element count—a 64-element probe will not run on a 16-channel instrument without a compatible phased array module.
  • Confirm wedge and wear-plate availability: the probe's footprint and mounting holes must match standard wedges for your pipe diameter or plate geometry.
  • Verify operating environment: probes rated for continuous contact need a replaceable wear face; high-temperature or immersion work requires a specific probe housing and cable jacket.