A laboratory water still is a dedicated distillation appliance that produces pyrogen-free, low-conductivity Type II or Type III reagent water for benchwork, media prep, and glassware rinsing. The core trade-off is still design: borosilicate glass with quartz or metal heaters delivers the highest purity and resistance to thermal shock, while stainless-steel or wall-mounted units trade peak purity for faster output, lower maintenance, and smaller footprints. Choose a glass still for critical analytical work where conductivity and pyrogen limits matter; choose a metal or compact still for routine washing, media, and high-volume feed where durability and throughput outweigh ultrapure specs.

Still Body Material:Borosilicate glass vs stainless steelDistillate Output:2–12 L/h (typical 4 L/h)Water Purity Grade:Type II/III; Type I needs polisherHeater Type:Quartz / borosilicate vs metal sheath

Key takeaways

  • Glass stills use borosilicate 3.3 vessels and quartz immersion heaters, yielding distillate with conductivity typically below 2 µS/cm and low pyrogen content; metal stills are more prone to trace metal carryover.
  • Output capacity spans roughly 2–12 L/h; stills above 4 L/h generally require a dedicated cooling-water feed or recirculating chiller to condense vapor efficiently.
  • Wall-mounted or bench-top metal stills with automatic cut-off and low-water protection are the standard for unattended operation; glass units demand manual monitoring and clean-in-place discipline.

At a glance

Price range
Varies by listing
Category
Lab Heating, Cooling & Vacuum Equipment
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • Glass stills use borosilicate 3.3 vessels and quartz immersion heaters, yielding distillate with conductivity typically below 2 µS/cm and low pyrogen content; metal stills are more prone to trace metal carryover.
  • Output capacity spans roughly 2–12 L/h; stills above 4 L/h generally require a dedicated cooling-water feed or recirculating chiller to condense vapor efficiently.
  • Wall-mounted or bench-top metal stills with automatic cut-off and low-water protection are the standard for unattended operation; glass units demand manual monitoring and clean-in-place discipline.
  • Storage tanks range from 4 to 20 L; a 10 L tank paired with a 4 L/h still covers a typical 8-hour bench day without repeated draws, while ultrapure polishing cartridges are a separate downstream module.

Best use cases

  • Best fit: analytical labs doing HPLC, ICP-MS, or trace-metal work should pick a borosilicate glass still with quartz heater and a dedicated storage reservoir; skip stainless units that can leach iron and nickel into distillate.
  • Best fit: busy teaching or clinical labs rinsing glassware and preparing non-critical media should choose a wall-mounted stainless still at 4–8 L/h with auto low-water cut-off; skip glass units that need constant operator attention.
  • Best fit: small bench or field stations with intermittent demand should pick a compact 2–4 L/h still with integrated 4–10 L tank and standard 120/230 V plug; skip high-output models that demand chilled water plumbing.
  • Wrong fit: any lab needing Type I ultrapure water (18.2 MΩ·cm) should not rely on a still alone—pair distillation with a deionizer/polisher stage or select a combined still-and-polisher system.

Buying tips

  • Size output to daily demand: allow 1 L/h of still capacity for every 4–6 L of daily Type II use, and add a storage tank at least twice the hourly output to buffer peak draws.
  • Match heater material to application: quartz or borosilicate-sheathed heaters resist thermal shock and ionic leaching; stainless-sheathed heaters are acceptable only for general rinsing and media prep.
  • Verify cooling: condensers need a continuous 1–2 L/min cooling-water flow at ≤25 °C; without a chiller or recirculator, high-output stills will vapor-lock or run dry.
  • Confirm electrical standard: most benchtop stills draw 2–3 kW at 120 V or 230 V; check plug type and circuit ampacity before committing to a wall-mounted unit.

Specs

Still Body MaterialBorosilicate glass vs stainless steel
Distillate Output2–12 L/h (typical 4 L/h)
Water Purity GradeType II/III; Type I needs polisher
Heater TypeQuartz / borosilicate vs metal sheath

Related searches

What to check before buying

  • Measure bench or wall space: allow 30–50 cm width and 40–60 cm height clearance, plus headroom for the condenser and reservoir; wall-mounted units need stud or bracket-rated mounting.
  • Confirm water feed quality and pressure: stills tolerate tap up to ~500 µS/cm; hard water above 300 mg/L CaCO3 requires pre-softening to prevent scale on heaters.
  • Check drain and cooling-water access: locate a floor drain or sink within hose reach and verify a cold-water tap delivering 1–2 L/min at ≤25 °C.
  • Verify electrical circuit: dedicated 15 A/120 V or 10 A/230 V circuit recommended; GFCI protection required for any still plumbed near a sink.