Bench & Gauge

Fluke 1587 Fc Insulation Multimeter Buying Guide

The Fluke 1587 FC is a dedicated insulation multimeter combining a 1 kV insulation tester with a True-RMS 1000 V CAT IV digital multimeter in one handheld unit. The core trade-off is between the convenience of an all-in-one insulation-plus-DMM tool and the higher test voltage, higher accuracy, and longer runtime of dedicated single-function instruments. Buy the 1587 FC only if you need daily multimeter functions and periodic insulation testing up to 1 kV; choose a dedicated insulation tester if you routinely test motors, cables, or switchgear at 2.5 kV or 5 kV.

Insulation Test Voltage:50 / 100 / 250 / 500 / 1000 V DCInsulation Resistance:Up to 2 GΩDMM Safety Rating:CAT IV 1000 V / CAT III 600 VWireless Logging:Fluke Connect BLE (FC models only)

Key takeaways

  • Insulation test ranges: 50 V, 100 V, 250 V, 500 V, and 1000 V DC, with resistance measurement to 2 GΩ — adequate for low-voltage motors, cables, and panel insulation up to 1 kV class.
  • True-RMS AC/DC multimeter section: 1000 V CAT IV / 600 V CAT III safety rating, 10 A current range, capacitance, frequency, diode, and continuity — a full-function DMM, not a stripped-down add-on.
  • Fluke Connect wireless (BLE) pairs with the Fluke Connect app for remote logging, trend capture, and report export; the FC suffix denotes this wireless module versus the non-FC 1587.

At a glance

Price range
Varies by listing
Category
Multimeters & Electrical Testers
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • Insulation test ranges: 50 V, 100 V, 250 V, 500 V, and 1000 V DC, with resistance measurement to 2 GΩ — adequate for low-voltage motors, cables, and panel insulation up to 1 kV class.
  • True-RMS AC/DC multimeter section: 1000 V CAT IV / 600 V CAT III safety rating, 10 A current range, capacitance, frequency, diode, and continuity — a full-function DMM, not a stripped-down add-on.
  • Fluke Connect wireless (BLE) pairs with the Fluke Connect app for remote logging, trend capture, and report export; the FC suffix denotes this wireless module versus the non-FC 1587.
  • Insulation test modes include PI (Polarization Index) and DAR (Dielectric Absorption Ratio) timed tests plus a 1-minute to 10-minute timed test, with live circuit detection that blocks output above 30 V to protect the instrument.

Best use cases

  • Best fit: industrial maintenance technicians who perform daily voltage/current/resistance checks and periodic 500 V or 1000 V insulation tests on motors, pumps, and LV distribution — one tool covers both jobs.
  • Best fit: field service engineers who need Fluke Connect wireless logging and report export for preventive-maintenance documentation on 480 V and 600 V systems.
  • Wrong fit: EV/hybrid high-voltage battery pack or 2.5 kV/5 kV cable testing — the 1587 FC tops out at 1 kV; step up to a dedicated 5 kV insulation tester such as the Fluke 1555.
  • Wrong fit: bench electronics or low-voltage hobby work — a standard 600 V CAT III DMM plus a separate low-voltage insulation tester is cheaper and more precise for 50 V insulation checks.

Buying tips

  • Match test voltage to equipment class: use 500 V DC for 480 V motors and cables, 250 V for 240 V circuits, and 1000 V only for 600 V–1 kV class equipment — higher voltage than the insulation rating can damage equipment.
  • Confirm True-RMS and CAT IV 1000 V / CAT III 600 V rating on the meter face; CAT IV covers service-entrance and outdoor conductors, CAT III covers distribution panels and feeders.
  • The FC wireless module is the only functional difference from the standard 1587; skip the FC premium if you do not need Fluke Connect app logging and reporting.
  • Budget for the correct probe set: TL75 hard-point test leads and an AC285 alligator clip set are standard; insulation tests require the longer lead and clip combinations rated for 1 kV.

Specs

Insulation Test Voltage50 / 100 / 250 / 500 / 1000 V DC
Insulation ResistanceUp to 2 GΩ
DMM Safety RatingCAT IV 1000 V / CAT III 600 V
Wireless LoggingFluke Connect BLE (FC models only)

Related searches

What to check before buying

  • Verify your insulation test voltage need does not exceed 1 kV DC — the 1587 FC cannot test 2.5 kV or 5 kV equipment, so confirm motor/cable nameplate insulation class before buying.
  • Check that your Fluke Connect workflow uses a supported iOS or Android device and that BLE pairing is acceptable in your facility's wireless policy.
  • Confirm the meter ships with the correct regional plug/charger for its AA battery configuration and that you have spare AA cells — insulation testing drains batteries faster than DMM-only use.
  • Measure your test-point access: the 1587 FC uses standard 4 mm banana jacks and a separate insulation test lead set; verify your panel spacing and probe reach before committing.

FAQ

All Multimeters & Electrical Testers buying guides

Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.

Some links on this page are affiliate links. If you buy after clicking one, we may earn a commission at no extra cost to you. This does not change which products appear here or their order. Affiliate disclosure.