Photos from current listings. Actual item, color, and included accessories may vary.
Fluke Multimeter Buying Guide
Fluke multimeters are professional-grade test instruments defined by true-RMS measurement, CAT III/IV safety ratings, and long-term calibration stability. The core trade-off is price versus safety margin and feature depth: industrial electricians need high-energy CAT ratings and non-contact voltage detection, while bench electronics work favors resolution, capacitance, and data logging. The decision rule is simple: buy the lowest CAT III/IV rated Fluke that covers your highest-energy environment, then add only the features you will actually use daily.
Median $288.63 · New & pre-owned listings
Key takeaways
- True-RMS AC measurement is standard across the 110/170/80 series; averaging-only meters misread distorted waveforms on VFDs and switch-mode supplies.
- CAT III 600V to CAT IV 600V ratings separate electrician-safe models (117, 179) from bench-only meters; CAT IV covers service-entrance and outdoor feeder work.
- The 170 series (175/177/179) adds 0.09% basic DC accuracy and 6000-count resolution; the 179 adds temperature and built-in non-contact voltage detection.
At a glance
- Category
- Multimeters & Electrical Testers
- Last updated
- Nov 28, 2026
Current offers
Fluke 187 True RMS Digital Multimeter$227.50Seller refurbished · Last checked Nov 21, 2026View on eBay
Fluke 115 True RMS Field Technicians Digital Multimeter, 600V AC/DC Voltage$253.83New · Last checked Nov 21, 2026View on eBay
Fluke 1503 Digital Insulation Resistance Tester HighPrecision Megger Multimeter$267.50New · Last checked Nov 21, 2026View on eBay
New In Box FLUKE 1503 F1503 Digital Insulation Resistance Tester Megger Meter L$309.76Last checked Nov 14, 2026View on eBay
Fluke 88 Automotive Digital Multimeter Tester Kit w/ Case Leads Manual$329.99Used · Last checked Nov 21, 2026View on eBay
Fluke 179/EDA2 6 Piece Industrial Electronics Multimeter Combo Kit$449.99Last checked Nov 18, 2026View on eBay
Highlights
- True-RMS AC measurement is standard across the 110/170/80 series; averaging-only meters misread distorted waveforms on VFDs and switch-mode supplies.
- CAT III 600V to CAT IV 600V ratings separate electrician-safe models (117, 179) from bench-only meters; CAT IV covers service-entrance and outdoor feeder work.
- The 170 series (175/177/179) adds 0.09% basic DC accuracy and 6000-count resolution; the 179 adds temperature and built-in non-contact voltage detection.
- The Fluke 1507 insulation tester outputs 50V/100V/250V/500V/1000V test voltages with PI/DAR ratios, while the 1503 covers 500V/1000V insulation ranges only.
Best use cases
- Industrial and commercial electricians: choose the Fluke 179 or 117 for CAT III 600V safety, true-RMS, and non-contact voltage detection; skip the 1503/1507 unless insulation resistance testing is a routine task.
- Motor and cable maintenance: pick the Fluke 1507 for 1000V insulation testing with polarization index and dielectric absorption ratio; the 1503 is the right cheaper tier when only 500V/1000V spot insulation checks are needed.
- Electronics bench and hobby work: the Fluke 179/EDA2 combo kit covers DC accuracy, capacitance, and temperature; skip CAT IV industrial models if you never work on live distribution panels.
- HVAC and field service: the 116 or 117 with clamp accessories covers temperature and microamps; do not buy an insulation tester as your only meter because it lacks standard voltage/current/resistance modes.
Buying tips
- Match the CAT rating to the panel: CAT III 600V covers distribution boards and fixed wiring; CAT IV 600V is required for service entrances and outdoor feeders.
- Count resolution before buying: 6000-count models (170 series) resolve 0.1mV/0.1mA; 4000-count models (110 series) are coarser for low-level electronics work.
- Insulation testers are specialty meters: the 1507 adds 50V/100V/250V/500V/1000V output plus PI/DAR; the 1503 stops at 500V/1000V with no ratio calculations.
- Verify fuse and lead standards: Fluke meters use 11A/1000V high-energy fuses and silicone-insulated probes rated CAT III/IV; aftermarket leads must carry the same CAT rating as the meter.
Specs
| Measurement Type | True-RMS AC / Average-responding |
|---|---|
| Safety Rating | CAT III 600V to CAT IV 600V |
| Display Counts | 4000 to 6000 counts |
| Insulation Test Voltage | 500V / 1000V (1503, 1507) |
Related searches
What to check before buying
- Confirm your highest-energy work environment: service entrance or outdoor feeder work demands CAT IV 600V; indoor distribution panels need CAT III 600V minimum.
- Check probe and accessory compatibility: Fluke 170 series uses standard 4mm shrouded banana jacks; the 1507 insulation tester requires its own test leads rated for 1000V.
- Verify calibration status: used Fluke meters should include a current calibration certificate or be priced for recertification; calibration drift matters most on 0.09%-accuracy 170-series units.
- Plan for companion parts: current clamps (iFlex or jaw) are separate purchases for the 117/179; the 179/EDA2 kit bundles leads, clips, and temperature probe to avoid add-on costs.
FAQ
Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.
Some links on this page are affiliate links. If you buy after clicking one, we may earn a commission at no extra cost to you. This does not change which products appear here or their order. Affiliate disclosure.