Bench & Gauge

Photos from current listings. Actual item, color, and included accessories may vary.

Fluke Multimeter Tester Buying Guide

Fluke multimeters and testers are professional-grade electrical measurement tools defined by True RMS accuracy, CAT III/IV safety ratings, and lifetime-warranty build quality. The core trade-off is between the ruggedized 170/87V series for industrial and field use versus the compact 11x/12x series for basic bench and HVAC tasks. The decision rule: buy a True RMS model rated CAT III 600V or higher with a specified DC accuracy of ±0.5% or better; skip any meter lacking a stated CAT safety rating or True RMS for AC work.

Measurement Type:True RMS vs average-sensingSafety Category:CAT III 600V / CAT IV 600VDC Accuracy:±0.05% to ±0.5%Battery Type:9V (170/87V) / AAA (11x)
Typical price range$227.50 – $449.99

Median $267.50 · New & pre-owned listings

Key takeaways

  • True RMS measurement is standard on 177/179/87V and mandatory for accurate readings on variable-frequency drives, inverters, and non-linear loads; the 113/114/115 series offers True RMS only on select models.
  • CAT III 600V and CAT IV 600V ratings are the decisive safety tiers—CAT IV covers service-entrance and outdoor conductors, CAT III covers distribution panels and fixed installations.
  • The 87V adds built-in temperature measurement via bead probe, 4-20 mA loop testing, and a high-accuracy 0.05% DC spec; the 179 matches True RMS with temperature but omits loop power and 4-20 mA sourcing.

At a glance

Category
Multimeters & Electrical Testers
Last updated
Nov 28, 2026

Current offers

Highlights

  • True RMS measurement is standard on 177/179/87V and mandatory for accurate readings on variable-frequency drives, inverters, and non-linear loads; the 113/114/115 series offers True RMS only on select models.
  • CAT III 600V and CAT IV 600V ratings are the decisive safety tiers—CAT IV covers service-entrance and outdoor conductors, CAT III covers distribution panels and fixed installations.
  • The 87V adds built-in temperature measurement via bead probe, 4-20 mA loop testing, and a high-accuracy 0.05% DC spec; the 179 matches True RMS with temperature but omits loop power and 4-20 mA sourcing.
  • The 170 series uses a sealed, drop-rated case with 1000V CAT III/600V CAT IV rating and a 9V battery; the compact 11x series uses a smaller case with 600V CAT III and 2 AAA batteries, suited to low-voltage electronics.

Best use cases

  • Industrial maintenance and panel troubleshooting: choose the Fluke 87V or 179 with CAT IV 600V rating, True RMS, and 4-20 mA loop capability—skip compact 11x models that lack CAT IV and loop sourcing.
  • HVAC and field diagnostics: pick the 116 or 179 with built-in temperature and microamp measurement; skip bench-only meters without a thermocouple input or True RMS.
  • Electronics bench and low-voltage prototyping: the 115 or 117 compact True RMS models are sufficient and cheaper; skip the 87V's loop and temperature features you won't use.
  • High-energy service entrance or outdoor feeder testing: only a CAT IV 600V-rated 87V or 179 is appropriate; never use a CAT II or unrated meter on service conductors.

Buying tips

  • Match the CAT rating to the installation: CAT IV 600V for service entrance and outdoor feeders, CAT III 600V minimum for distribution panels and fixed wiring, CAT II for portable appliances only.
  • Require True RMS and a stated DC accuracy of ±0.5% or better for any AC measurement on motors, drives, or inverters; non-True-RMS meters misread distorted waveforms by 10-30%.
  • Choose the 87V over the 179 if you need 4-20 mA loop troubleshooting and 0.05% DC accuracy; choose the 179 if temperature measurement in a sealed CAT IV case is the priority.
  • For compact field kits, the 117 includes non-contact voltage detection and True RMS in a CAT III 600V package; the 113 drops True RMS and is best for basic go/no-go checks.

Specs

Measurement TypeTrue RMS vs average-sensing
Safety CategoryCAT III 600V / CAT IV 600V
DC Accuracy±0.05% to ±0.5%
Battery Type9V (170/87V) / AAA (11x)

Related searches

What to check before buying

  • Confirm your panel or feeder voltage and category: 480V three-phase panels require CAT III 600V minimum; service-entrance and outdoor conductors require CAT IV 600V.
  • Check test-lead ratings separately—the meter's CAT rating is only valid with matching CAT-rated probes and leads; standard leads shipped with compact models may be CAT II only.
  • Verify battery type and runtime: 9V for 170/87V series, AAA for 11x series; keep a spare of the correct cell for field work.
  • Confirm the kit includes the probe set and temperature bead you need—combo kits add accessories, but base meters ship with standard TL75 or TL71 leads only.

FAQ

All Multimeters & Electrical Testers buying guides

Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.

Some links on this page are affiliate links. If you buy after clicking one, we may earn a commission at no extra cost to you. This does not change which products appear here or their order. Affiliate disclosure.