Horiba Raman Spectroscopy Buying Guide
Horiba Raman spectrometers span bench-top research microscopes to portable handheld analyzers, all built around dispersive grating spectrographs and thermoelectrically cooled CCD or InGaAs detectors. The core trade-off is spectral resolution and laser choice versus portability and fluorescence rejection—instruments with 785 nm or 1064 nm excitation and deep-cooled detectors handle fluorescent samples, while 532 nm systems deliver higher Raman cross-section but excite more background. Choose a system whose laser wavelength, spectral range, and detector cooling match your sample chemistry and throughput; skip anything with fixed-focus optics or uncooled detectors if you need trace detection or quantitative work.
Key takeaways
- Laser excitation options include 532 nm for high signal, 638/785 nm for fluorescence reduction, and 1064 nm for maximum fluorescence rejection in organics and biologicals.
- Detector choices are thermoelectrically cooled back-thinned CCD (high sensitivity, visible-NIR) or InGaAs arrays (for 1064 nm systems), with cooling temperature directly affecting dark noise and integration times.
- Spectral resolution is set by grating groove density and slit width; high-resolution configurations reach <2 cm⁻¹ but reduce throughput, while standard configurations trade resolution for faster acquisition.
At a glance
- Price range
- Varies by listing
- Category
- Spectroscopy, Analysis & Detection Instruments
- Last updated
- Nov 28, 2026
Current offers
Highlights
- Laser excitation options include 532 nm for high signal, 638/785 nm for fluorescence reduction, and 1064 nm for maximum fluorescence rejection in organics and biologicals.
- Detector choices are thermoelectrically cooled back-thinned CCD (high sensitivity, visible-NIR) or InGaAs arrays (for 1064 nm systems), with cooling temperature directly affecting dark noise and integration times.
- Spectral resolution is set by grating groove density and slit width; high-resolution configurations reach <2 cm⁻¹ but reduce throughput, while standard configurations trade resolution for faster acquisition.
- Horiba's LabSpec and XploRA lines offer confocal microscopy with motorized stages for mapping, while handheld MicOS and portable i-Raman systems prioritize field use with fiber-optic probes.
Best use cases
- Best fit: materials science labs doing phase identification and stress mapping should pick a benchtop confocal system (e.g., LabSpec or XploRA) with 532/785 nm dual lasers and a motorized XYZ stage; skip handhelds for sub-micron spatial resolution.
- Best fit: pharmaceutical or forensic field screening requires a portable 785 nm or 1064 nm analyzer with library matching and battery operation (e.g., MicOS or i-Raman); skip open-beam bench systems for uncontrolled environments.
- Best fit: biological and polymer samples with strong fluorescence should use 1064 nm excitation with an InGaAs detector, accepting lower signal-to-noise for cleaner spectra; skip 532 nm systems for these samples.
Buying tips
- Match laser wavelength to sample fluorescence: 532 nm for carbon and inorganic materials, 785 nm for general organics and SERS, 1064 nm for highly fluorescent biologicals and polymers.
- Check spectral resolution against your application: <2 cm⁻¹ for crystalline polymorph discrimination, <4 cm⁻¹ for general chemical identification, and wider for fast screening.
- Confirm detector cooling: thermoelectric cooling to -60 °C or lower is needed for trace detection and long integrations; uncooled or shallow-cooled detectors suit only strong Raman scatterers.
- Verify fiber-optic probe compatibility and laser safety class—Class 3B lasers require interlocked enclosures or strict administrative controls in open-beam setups.
Specs
| Laser Excitation | 532 / 638 / 785 / 1064 nm |
|---|---|
| Detector Type | TE-cooled CCD or InGaAs |
| Spectral Resolution | <2 to 8 cm⁻¹ (grating-dependent) |
| Form Factor | Benchtop confocal / portable handheld |
Related searches
What to check before buying
- Measure your sample size and working distance: confocal microscopes need compatible objective lenses and a stage that fits your sample holder; portable probes require direct contact or immersion access.
- Check laboratory power: benchtop systems typically require 100–240 V AC with stable supply; portable units need battery charge time and spare battery availability for full-day field use.
- Confirm data output and software: Horiba systems use LabSpec 6 software; ensure your PC meets its OS and RAM requirements and that exported formats (SPC, TXT, CSV) match your analysis pipeline.
- Verify laser safety compliance for your site: Class 3B or 4 lasers require warning signs, key control, and eye protection; enclosed benchtop systems simplify compliance versus open-beam portables.