Tga Thermal Analysis Buying Guide
A TGA (thermogravimetric analyzer) measures mass change versus temperature to quantify composition, thermal stability, and decomposition kinetics. The core trade-off is between sensitive microbalances with wide temperature range and affordable single-furnace units with limited atmosphere control. Buy a TGA only if you need quantitative mass-loss data at programmed temperatures; otherwise a DSC or TGA-DSC combined unit covers most routine work.
Balance Resolution:0.1 µg research / 1 µg routineMax Temperature:1000-1200 °C standard / 1500-1600 °C high-tempAtmosphere Control:Single gas vs multi-MFC switchingCrucible Material:Alumina / Platinum / Quartz
Key takeaways
- Balance sensitivity: research-grade TGA resolves 0.1 µg or better; routine/industrial units resolve 1 µg, which is adequate for percent-level composition but not for trace volatile detection.
- Furnace temperature range: standard TGA tops out at 1000–1200 °C (platinum or Kanthal elements); high-temperature models reach 1500–1600 °C with tungsten or graphite furnaces requiring inert purge.
- Atmosphere control: true TGA requires gas switching (N2, air, O2, Ar) with mass-flow controllers; single-gas units cannot run oxidative stability or evolved-gas switching tests without manual retrofit.
At a glance
- Price range
- Varies by listing
- Category
- Spectroscopy, Analysis & Detection Instruments
- Last updated
- Nov 28, 2026
Current offers
Highlights
- Balance sensitivity: research-grade TGA resolves 0.1 µg or better; routine/industrial units resolve 1 µg, which is adequate for percent-level composition but not for trace volatile detection.
- Furnace temperature range: standard TGA tops out at 1000–1200 °C (platinum or Kanthal elements); high-temperature models reach 1500–1600 °C with tungsten or graphite furnaces requiring inert purge.
- Atmosphere control: true TGA requires gas switching (N2, air, O2, Ar) with mass-flow controllers; single-gas units cannot run oxidative stability or evolved-gas switching tests without manual retrofit.
- Crucible material must be matched to max temperature and sample reactivity: alumina to ~1700 °C, platinum to ~1600 °C (avoid Pt with metals that alloy), quartz to ~1100 °C; sample mass typically 1–50 mg.
Best use cases
- Best fit: polymer/plastics lab measuring filler content, moisture, and decomposition onset — choose a 1000 °C TGA with 1 µg resolution and air/N2 switching; skip 1600 °C furnaces you will never use.
- Best fit: battery or catalyst R&D needing oxidative/reductive cycling — pick a TGA with automated multi-gas MFC control and a platinum crucible; a single-gas unit is a false economy.
- Best fit: QA/QC incoming-material screening at percent-level precision — a rugged 1 µg industrial TGA with autosampler is sufficient; research-grade 0.1 µg balances add cost without practical benefit.
- Wrong fit: sub-ambient or high-pressure studies — a standard TGA cannot hold vacuum/pressure or cool below room temperature; you need a dedicated high-pressure or low-temperature TGA/DSC.
Buying tips
- Match furnace max temperature to your highest decomposition event plus 100 °C margin; a 1000 °C TGA handles most polymers, but ceramics and metal oxalates demand 1500 °C+.
- Choose balance resolution by the smallest mass change you must report: 1 µg for percent-level (0.1% of 1 mg), 0.1 µg for sub-percent trace volatiles.
- Require integrated mass-flow controllers for each gas line; manual needle valves produce drifting baselines and non-reproducible oxidative onset temperatures.
- Verify crucible compatibility: platinum crucibles react with molten metals and carbon; alumina is inert but prone to thermal shock; quartz is cheap but limited to ~1100 °C.
Specs
| Balance Resolution | 0.1 µg research / 1 µg routine |
|---|---|
| Max Temperature | 1000-1200 °C standard / 1500-1600 °C high-temp |
| Atmosphere Control | Single gas vs multi-MFC switching |
| Crucible Material | Alumina / Platinum / Quartz |
Related searches
What to check before buying
- Bench space and power: confirm 220–240 V or 110–120 V match, dedicated circuit, and clearance for furnace cooling (many units need 30–50 cm rear/side ventilation).
- Purge gas supply: ensure regulated N2/Ar/air lines at 99.999% purity and 1–5 bar; install an oxygen trap for sub-ppm O2 work in high-temperature furnaces.
- Balance location: place on a vibration-isolated bench away from fume hoods and HVAC drafts; microbalances drift with air currents and floor vibration.
- Sample preparation tools: budget for a microbalance (0.1 µg readability), crucible press/tweezers, and crimper if using hermetic pans for TGA-DSC.
FAQ
Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.
Some links on this page are affiliate links. If you buy after clicking one, we may earn a commission at no extra cost to you. This does not change which products appear here or their order. Affiliate disclosure.