GE PQM II Buying Guide
The GE PQM II is a panel-mount three-phase power quality meter designed for continuous monitoring of voltage, current, power, demand, harmonics, and waveform capture in industrial and commercial switchgear. Unlike handheld multimeters, it is a permanently installed device requiring external current transformers (CTs) and a control power source, and its value depends on correct CT sizing, wiring configuration, and communication options rather than portability. The decision rule is simple: buy a PQM II only if you need fixed-mount, CT-based three-phase power quality data with Modbus or analog outputs; choose a portable power quality analyzer or clamp meter for temporary troubleshooting.
Key takeaways
- Three-phase panel-mount architecture: accepts 3-phase 3-wire or 4-wire systems via external CTs and direct voltage inputs, not a hand-held probe-based meter.
- Measures true RMS voltage, current, real/reactive/apparent power, power factor, demand, and energy, with harmonics analysis and waveform capture for power quality diagnostics.
- Communication and I/O options include Modbus RTU over RS-485 and analog outputs; exact feature set varies by firmware and option module installed in the unit.
At a glance
- Category
- Multimeters & Electrical Testers
- Status
- Listings available
- Last updated
- Nov 28, 2026
Current offers
Highlights
- Three-phase panel-mount architecture: accepts 3-phase 3-wire or 4-wire systems via external CTs and direct voltage inputs, not a hand-held probe-based meter.
- Measures true RMS voltage, current, real/reactive/apparent power, power factor, demand, and energy, with harmonics analysis and waveform capture for power quality diagnostics.
- Communication and I/O options include Modbus RTU over RS-485 and analog outputs; exact feature set varies by firmware and option module installed in the unit.
- Control power must match the unit's nameplate rating (typically 120-240 V AC/DC or 24-48 V DC depending on variant); wrong control voltage is the most common installation failure.
Best use cases
- Best fit: permanent monitoring inside industrial switchgear, panelboards, or motor control centers where you need continuous three-phase power quality data logged to a SCADA or BMS via Modbus.
- Best fit: replacing or upgrading an existing panel meter in a plant with available CTs and a 120-240 V control circuit, especially where harmonic distortion and demand tracking are required.
- Wrong fit: temporary troubleshooting or residential/light-commercial spot checks—use a portable power quality analyzer or true-RMS clamp meter instead, since the PQM II needs CTs and permanent wiring.
- Wrong fit: single-phase or low-voltage DC systems—the PQM II is designed for three-phase AC power systems and will not provide meaningful data on DC or basic single-phase branch circuits.
Buying tips
- Verify the control power rating on the unit's label before purchase: 120-240 V AC/DC and 24-48 V DC variants exist, and the wrong supply will prevent boot or damage the meter.
- Match CT secondary rating to the meter's input (5 A or 1 A) and ensure CT ratio is programmable in the setup; mismatched CTs produce scaled current and power errors.
- Confirm the communication option installed: Modbus RTU RS-485 is standard on many PQM II units, but analog output or Ethernet options depend on the specific model and firmware.
- Check that the panel cutout and depth fit your enclosure; the PQM II is a square panel-mount meter requiring a specific cutout and rear clearance for wiring and CT leads.
Specs
| Install Type | Panel-mount, 3-phase |
|---|---|
| Current Input | External CT, 5 A or 1 A secondary |
| Comms | Modbus RTU RS-485 / analog opt. |
| Control Power | 120-240 V AC/DC or 24-48 V DC |
Alternatives to compare
Related searches
What to check before buying
- Measure your panel cutout and rear clearance: the PQM II needs a square cutout per its datasheet and enough depth behind the panel for CT wiring and communication cables.
- Confirm your system voltage and CT secondary: 3-phase 3-wire or 4-wire, and CTs with 5 A or 1 A secondary matching the meter's current input rating.
- Verify control power available at the panel: 120-240 V AC/DC or 24-48 V DC per the unit's nameplate, with a dedicated fused circuit.
- Check communication infrastructure: RS-485 twisted pair for Modbus RTU with proper termination, or confirm analog output wiring if using 4-20 mA signals.